Concrete Kerb

Concrete Kerb

JDP branches offer a wide range of concrete kerbs as specified in the current version of BS EN 1340. Due to JDP's close partnerships with the industry's leading manufacturers we can ensure customers are provided with leading branch quality products from their local branch.

Features & Benefits

All straight units and the majority of radius units are hydraulically pressed. Other radius units are hammer-compacted.

  • Complies with British Standards
  • Designed to withstand occasional vehicular impact

Kerbs / Application Selector

Pole Boxes Pole Boxes Pole Boxes
  Access Kerb HGV Kerb BS Kerb
Trafficking
  • Designed to withstand occasional bus impact
  • Designed to withstand occasional HGV impact while directing vehicle wheels back on to roadway
  • Designed to withstand occasional bus impact
Features
  • Wide range of profiles to suit access requirements
  • Integral marker bump
  • High strength for busy routes
  • Damage resistant
  • Will accept signage
  • Meets British Standards
Accessories
  • Dropper units
  • Quadrants to certain profiles
  • Radius units
  • Dropper units
  • Quadrants
  • Crossing units
  • Dropper units
  • Radius kerbs
  • Internal and external angles
  • Quadrants
  • Offlets
  • Marginal strips
  • Marker channels
  • Non standard options
Colours
  • Grey
  • Grey
  • Grey
Textures
  • Standard
  • Natural granite
  • Standard
  • Standard

Half Battered BS Kerbs

Half battered kerbs are designed with safety in mind to deflect vehicles travelling at low speeds back into the main carriageway and away from pedestrians using footways.

Applications

  • Commercial sites
  • Industrial sites
  • City roads
  • Urban areas

Half Battered BS Kerbs

Standard Kerb

Standard Kerbs

Code Description
180100866 150x305 HB1
180100860 125x255 HB2
180100855 125x150 HB3
Crossing Kerb

Droppers and Crossing Kerbs

Code Description
180101704 125x255mm HB - 125x150mm BN (LH) DL1
180101705 125x255mm HB - 125x150mm BN (RH) DR1
180100658 125x150mm BN As Crossing Kerb
Standard Kerb

Radius Droppers (Available in 4, 5, 6,8 and 10m External Radius Only)

Code Code Description
LH RH  
180141369 180141368 125x255mm HB - 125x150mm BN 4m
180141371 180141370 125x255mm HB - 125x150mm BN 5m
180141373 180141372 125x255mm HB - 125x150mm BN 6m
180141375 180141374 125x255mm HB - 125x150mm BN 8m
180141377 180141376 125x255mm HB - 125x150mm BN 10m
Radius Kerbs

Radius Kerbs & Channels

125x255 HB External 125x255 HB Internal 125x150 BN Channel External 125x150 BN Channel Internal Size of Radius Units per 1/4 circle
180141318 - - - 0.5 1
180140755 180141319 180141321 - 1 2
180140849 180141320 180141178 - 2 4
180140850 180141042 180141179 180141202 3 6
180140851 180141043 180141180 180141203 4 8
180140852 180141044 180141181 180141204 5 10
180140853 180141045 180141182 180141205 6 12
180140854 180141046 180141183 180141206 8 16
180140855 180141047 180141184 180141207 10 20
180140856 180141048 180141185 180141208 15 30

The table shown is an approximate guide only.

All radii over 15 m (40 ft) can be achieved by using standard 914 mm (3 ft) or 609 mm (2 ft) kerbs.

Before ordering, check availability of size and profile.

Also when ordering, please state the dimensions first, then the profile, then the radii followed by Internal or External. e.g. 125x150 HB 6M Ext.

Quadrant

Quadrants

Code Description
180100854 305x255mm QHB
180100853 455x255mm QHB
Transition Kerb

Transition Kerbs

Code Description
180101099 125x255mm HB RH - 125x255mm SP LH TR
180100983 125x255mm HB LH - 125x255mm SP RH TL
Pole Boxes

Angles

Code Description
180101177 125x255mm HB Ext Angle HBXA
180101218 125x255mm HB Int Angle HBIA

Bull Nose BS Kerbs

Bull nose kerbs are designed to sit just proud of the surface as a crossing kerb. For dropping kerbs see relevant Half Battered or Splayed BS Kerb section.

Applications

  • Commercial sites
  • City Roads
  • Industrial sites
  • Urban areas
Standard Bull Nose Kerb

Standard Kerbs

Code Description
180100666 125x255mm BN
180100658 125x150mm BN
Pole Boxes

Droppers and Crossing Kerbs

Code Description
180100738 125x255mm BN - 125x150mm BN (LH) Non BS
180100826 125x255mm SP - 125x150mm BN (RH) Non BS
180100658 125x150mm BN As Crossing Kerb
Pole Boxes

Quadrants

Code Description
180100657 305x255mm QBN
180100649 455x255mm QBN
Pole Boxes

Transition Kerbs

Code Description
180101099 125x255mm HB RH - 125x255mm SP LH TR
180100983 125x255mm HB LH - 125x255mm SP RH TL
Pole Boxes

Angles

Code Description
180140090 125x255mm BN Ext Angle
180140089 125x255mm BN Int Angle

Splayed BS Kerbs

Splayed kerbs are designed with safety in mind to allow vehicles travelling at high speeds to mount the kerb and preventing them from deflecting back into other vehicles on the main carriageway.

Applications

  • Highways
  • Carriageways
Splayed standard kerb

Standard Kerbs

Code Description
180100780 125x255mm SP
Pole Boxes

Droppers and Crossing Kerbs

Code Description
180100879 125x255mm SP - 125x150mm BN (LH) DL2
180100952 125x255mm SP - 125x150mm BN (RH) DR2
180100658 125x150mm BN As Crossing Kerb
Pole Boxes

Radius Kerbs & Channels

125x255 SP External 125x150 BN Channel External 125x150 BN Channel Internal Size of Radius Units per 1/4 circle
- - - 0.5 1
180141399 180141321 - 1 2
180141194 180141178 - 2 4
180141195 180141179 180141202 3 6
180141196 180141180 180141203 4 8
180141197 180141181 180141204 5 10
180141198 180141182 180141205 6 12
180141199 180141183 180141206 8 16
180141200 180141184 180141207 10 20
180141201 180141185 180141208 15 30

Not available use HB.

The table shown is an approximate guide only.

All radii over 15m (40ft) can be achieved by using standard 914mm (3ft) or 609mm (2ft) kerbs.

Before ordering, check availability of size and profile.

Also when ordering, please state the dimensions first, then the profile, then the radii followed by Internal or External. e.g 125x150 HB 6m Ext

Pole Boxes

Quadrants

Code Description
180100775 305x255mm QSP
Pole Boxes

Transition Kerbs

Code Description
180101099 125x255mm SP Ext Angle SPXA
180100753 125x255mm SP Int Angle SPIA
Pole Boxes

Angles

Code Description
180100593 125x255mm SP Ext Angle SPXA
180100753 125x255mm SP Int Angle SPIA
Pole Boxes

Channels - Square, Dished, Fluted & Motorway

Code Description  
180100925 150x100x914mm Square
180100926 150x125x914mm (CS2) Square
180100931 150x150x914mm Square
180100928 255x125x914mm (CS1) Square
180100932 305x150x914mm Square
180100985 150x100x914mm Dished
180101132 255x125x914mm (200x25) Dished
180100990 305x150x914mm (230x25) Dished
180101100 255x75x914mm Fluted
180101083 455x150x914mm (18"x16") Motorway

Edging Kerb

Edging kerbs are designed to retain the surface structure between the roadside kerb and the loose ground, such as pavements.

Applications

  • City roads
  • Urban areas
  • Highways
  • Carriageways
  • Commercial sites
  • Industrial sites
Edging Kerb
Code Description
180100576 50x150x914 Edging Kerb Flat Top EF
180100589 50x205x914 Edging Kerb Flat Top EF
180100569 50x150x914 Bullnose Edging EBN
180101072 50x205x914 Bullnose Edging EBN
180101615 50x150x914 Round Top Edging RT
180103772 50x205x914 Round Top Edging RT
1801 75x255x914 Round Top Edging RT

Installation

British Standard kerb products comply with the performance levels in European Standard BS EN 1340.

These products should be installed in accordance to BS7533 Part 6. They form edge restraints for other paving materials, pedestrian/vehicle segregation and drainage collectors for surface water. Foundations for units can either be a well compacted bed of fresh concrete or a 1:3 cement : sand mortar (12-40mm thick) on a preformed concrete race.

The base concrete, to grade ST1, should be a minimum 150mm thick and extended 150mm beyond the edge of the unit where haunching is required.

Haunching for units as appropriate should be with a concrete grade ST1. It is necessary to ensure a good bond between haunching concrete, unit and base. Allow to gain sufficient strength before laying adjacent paving material. Lay units to line and level with a paviours maul such as that they are within 3mm of the design alignment. Joints should be close joints (trowel thickness) for natural stone and concrete units, laid dry.

Technical Support

Our expert technical support team are on hand to offer assistance and support for all our products.